  jun-14-2004 1 bcr185.../semb9 pnp silicon digital transistor ? switching circuit, inverter, interface circuit, driver circuit ? built in bias resistor ( r 1 = 10k ? , r 2 = 47k ? ) ? for 6-pin packages: two (galvanic) internal isolated transistors with good matching in one package bcr185/f/l3 bcr185t/w bcr185s/u semb9 eha07183 3 2 1 c e b r 1 r 2 eha07173 6 54 3 2 1 c1 b2 e2 c2 b1 e1 1 r r 2 r 1 r 2 tr1 tr2 type markin g pin configuration package bcr185 bcr185f BCR185L3 bcr185s bcr185t bcr185u bcr185w semb9 wns wns wn wns wns wns wns wn 1=b 1=b 1=b 1=e1 1=b 1=e1 1=b 1=e1 2=e 2=e 2=e 2=b1 2=e 2=b1 2=e 2=b1 3=c 3=c 3=c 3=c2 3=c 3=c2 3=c 3=c2 - - - 4=e2 - 4=e2 - 4=e2 - - - 5=b2 - 5=b2 - 5=b2 - - - 6=c1 - 6=c1 - 6=c1 sot23 tsfp-3 tslp-3-4 sot363 sc75 sc74 sot323 sot666
jun-14-2004 2 bcr185.../semb9 maximum ratings parameter symbol value unit collector-emitter voltage v ceo 50 v collector-base voltage v cbo 50 emitter-base voltage v ebo 6 input on voltage v i(on) 20 collector current i c 100 ma total power dissipation- bcr185 t s 102c bcr185f, t s 128c BCR185L3, t s 135c bcr185s, t s 115c bcr185t, t s 109c bcr185u, t s 118c bcr185w, t s 124c semb9, t s 75c p tot 200 250 250 250 250 250 250 250 mw junction temperature t j 150 c storage temperature t stg -65 ... 150 thermal resistance parameter symbol value unit junction - soldering point 1) bcr185 bcr185f BCR185L3 bcr185s bcr185t bcr185u bcr185w semb9 r thjs 240 90 60 140 165 133 105 300 k/w 1 for calculation of r thja please refer to application note thermal resistance
jun-14-2004 3 bcr185.../semb9 electrical characteristics at t a = 25c, unless otherwise specified parameter symbol values unit min. typ. max. dc characteristics collector-emitter breakdown voltage i c = 100 a, i b = 0 v (br)ceo 50 - - v collector-base breakdown voltage i c = 10 a, i e = 0 v (br)cbo 50 - - collector-base cutoff current v cb = 40 v, i e = 0 i cbo - - 100 na emitter-base cutoff current v eb = 6 v, i c = 0 i ebo - - 167 a dc current gain 1) i c = 5 ma, v ce = 5 v h fe 70 - - - collector-emitter saturation voltage 1) i c = 10 ma, i b = 0,5 ma v cesat - - 0,3 v input off voltage i c = 100 a, v ce = 5 v v i(off) 0,5 - 1 input on voltage i c = 2 ma, v ce = 0,3 v v i(on) 0,5 - 1,4 input resistor r 1 7 10 13 k ? resistor ratio r 1 / r 2 0,19 0,21 0,24 - ac characteristics transition frequency i c = 10 ma, v ce = 5 v, f = 100 mhz f t - 200 - mhz collector-base capacitance v cb = 10 v, f = 1 mhz c cb - 3 - pf 1 pulse test: t < 300s; d < 2%
jun-14-2004 4 bcr185.../semb9 dc current gain h fe = ? ( i c ) v ce = 5 v (common emitter configuration) 10 -1 10 0 10 1 10 2 ma i c 0 10 1 10 2 10 3 10 - h fe collector-emitter saturation voltage v cesat = ? ( i c ), h fe = 20 0 0.2 0.4 0.6 v 1 v cesat 0 10 1 10 2 10 ma i c input on voltage v i (on) = ? ( i c ) v ce = 0.3v (common emitter configuration) 10 -1 10 0 10 1 10 2 v v i(on) -1 10 0 10 1 10 2 10 ma i c input off voltage v i(off) = ? ( i c ) v ce = 5v (common emitter configuration) 0 0.5 1 v 2 v i(off) -3 10 -2 10 -1 10 0 10 1 10 ma i c
jun-14-2004 5 bcr185.../semb9 total power dissipation p tot = ? ( t s ) bcr185 0 20 40 60 80 100 120 c 150 t s 0 50 100 150 200 mw 300 p tot total power dissipation p tot = ? ( t s ) bcr185f 0 20 40 60 80 100 120 c 150 t s 0 50 100 150 200 mw 300 p tot total power dissipation p tot = ? ( t s ) BCR185L3 0 20 40 60 80 100 120 c 150 t s 0 50 100 150 200 mw 300 p tot total power dissipation p tot = ? ( t s ) bcr185s 0 20 40 60 80 100 120 c 150 t s 0 50 100 150 200 mw 300 p tot
jun-14-2004 6 bcr185.../semb9 total power dissipation p tot = ? ( t s ) bcr185t 0 20 40 60 80 100 120 c 150 t s 0 50 100 150 200 mw 300 p tot total power dissipation p tot = ? ( t s ) bcr185u 0 20 40 60 80 100 120 c 150 t s 0 50 100 150 200 mw 300 p tot total power dissipation p tot = ? ( t s ) bcr185w 0 20 40 60 80 100 120 c 150 t s 0 50 100 150 200 mw 300 p tot total power dissipation p tot = ? ( t s ) semb9 0 20 40 60 80 100 120 c 150 t s 0 50 100 150 200 mw 300 p tot
jun-14-2004 7 bcr185.../semb9 permissible pulse load p totmax / p totdc = ? ( t p ) bcr185 10 -6 10 -5 10 -4 10 -3 10 -2 10 0 s t p 0 10 1 10 2 10 3 10 - p totmax / p totdc d = 0 0.005 0.01 0.02 0.05 0.1 0.2 0.5 permissible pulse load r thjs = ? ( t p ) bcr185 10 -6 10 -5 10 -4 10 -3 10 -2 10 0 s t p -1 10 0 10 1 10 2 10 3 10 k/w r thjs 0.5 0.2 0.1 0.05 0.02 0.01 0.005 d = 0 permissible pulse load p totmax / p totdc = ? ( t p ) bcr185f 10 -6 10 -5 10 -4 10 -3 10 -2 10 0 s t p 0 10 1 10 2 10 3 10 p totmax / p totdc d=0 0.005 0.01 0.02 0.05 0.1 0.2 0.5 permissible puls load r thjs = ? ( t p ) bcr185f 10 -6 10 -5 10 -4 10 -3 10 -2 10 0 s t p -1 10 0 10 1 10 2 10 k/w r thjs d=0.5 0.2 0.1 0.05 0.02 0.01 0.005 0
jun-14-2004 8 bcr185.../semb9 permissible puls load r thjs = ? ( t p ) BCR185L3 10 -7 10 -6 10 -5 10 -4 10 -3 10 -2 10 0 s t p -1 10 0 10 1 10 2 10 r thjs 0.5 0.2 0.1 0.05 0.02 0.01 0.005 d = 0 permissible pulse load p totmax / p totdc = ? ( t p ) BCR185L3 10 -7 10 -6 10 -5 10 -4 10 -3 10 -2 10 0 s t p 0 10 1 10 2 10 3 10 p totmax / p totdc d = 0 0.005 0.01 0.02 0.05 0.1 0.2 0.5 permissible puls load r thjs = ? ( t p ) bcr185s 10 -6 10 -5 10 -4 10 -3 10 -2 10 0 s t p -1 10 0 10 1 10 2 10 3 10 k/w r thjs 0.5 0.2 0.1 0.05 0.02 0.01 0.005 d = 0 permissible pulse load p totmax / p totdc = ? ( t p ) bcr185s 10 -6 10 -5 10 -4 10 -3 10 -2 10 0 s t p 0 10 1 10 2 10 3 10 - p totmax / p totdc d = 0 0.005 0.01 0.02 0.05 0.1 0.2 0.5
jun-14-2004 9 bcr185.../semb9 permissible puls load r thjs = ? ( t p ) bcr185t 10 -6 10 -5 10 -4 10 -3 10 -2 10 0 s t p -1 10 0 10 1 10 2 10 3 10 k/w r thjs d=0.5 0.2 0.1 0.05 0.02 0.01 0.005 0 permissible pulse load p totmax / p totdc = ? ( t p ) bcr185t 10 -6 10 -5 10 -4 10 -3 10 -2 10 0 s t p 0 10 1 10 2 10 3 10 p totmax / p totdc d=0 0.005 0.01 0.02 0.05 0.1 0.2 0.5 permissible puls load r thjs = ? ( t p ) bcr185u 10 -6 10 -5 10 -4 10 -3 10 -2 10 0 s t p -1 10 0 10 1 10 2 10 3 10 k/w r thjs d=0.5 0.2 0.1 0.05 0.02 0.01 0.005 0 permissible pulse load p totmax / p totdc = ? ( t p ) bcr185u 10 -6 10 -5 10 -4 10 -3 10 -2 10 0 s t p 0 10 1 10 2 10 3 10 p totmax / p totdc d=0 0.005 0.01 0.02 0.05 0.1 0.2 0.5
jun-14-2004 10 bcr185.../semb9 permissible puls load r thjs = ? ( t p ) bcr185w 10 -6 10 -5 10 -4 10 -3 10 -2 10 0 s t p -1 10 0 10 1 10 2 10 3 10 k/w r thjs 0.5 0.2 0.1 0.05 0.02 0.01 0.005 d = 0 permissible pulse load p totmax / p totdc = ? ( t p ) bcr185w 10 -6 10 -5 10 -4 10 -3 10 -2 10 0 s t p 0 10 1 10 2 10 3 10 - p totmax / p totdc d = 0 0.005 0.01 0.02 0.05 0.1 0.2 0.5 permissible puls load r thjs = ? ( t p ) semb9 10 -7 10 -6 10 -5 10 -4 10 -3 10 -2 10 0 s t p -1 10 0 10 1 10 2 10 3 10 k/w r thjs 0.5 0.2 0.1 0.05 0.02 0.01 0.005 d = 0 permissible pulse load p totmax / p totdc = ? ( t p ) semb9 10 -7 10 -6 10 -5 10 -4 10 -3 10 -2 10 0 s t p 0 10 1 10 2 10 3 10 p totmax / p totdc d = 0 0.005 0.01 0.02 0.05 0.1 0.2 0.5
published by infineon technologies ag, st.-martin-strasse 53, 81669 mnchen ? infineon technologies ag 200 4 . all rights reserved. attention please! the information herein is given to describe certain components and shall not be considered as a guarantee of characteristics. terms of delivery and rights to technical change reserved. we hereby disclaim any and all warranties, including but not limited to warranties of non-infringement, regarding circuits, descriptions and charts stated herein. information for further information on technology, delivery terms and conditions and prices please contact your nearest infineon technologies office (www.infineon.com). warnings due to technical requirements components may contain dangerous substances. for information on the types in question please contact your nearest infineon technologies office. infineon technologies components may only be used in life-support devices or systems with the express written approval of infineon technologies, if a failure of such components can reasonably be expected to cause the failure of that life-support device or system, or to affect the safety or effectiveness of that device or system. life support devices or systems are intended to be implanted in the human body, or to support and/or maintain and sustain and/or protect human life. if they fail, it is reasonable to assume that the health of the user or other persons may be endangered.


▲Up To Search▲   

 
Price & Availability of BCR185L3

All Rights Reserved © IC-ON-LINE 2003 - 2022  

[Add Bookmark] [Contact Us] [Link exchange] [Privacy policy]
Mirror Sites :  [www.datasheet.hk]   [www.maxim4u.com]  [www.ic-on-line.cn] [www.ic-on-line.com] [www.ic-on-line.net] [www.alldatasheet.com.cn] [www.gdcy.com]  [www.gdcy.net]


 . . . . .
  We use cookies to deliver the best possible web experience and assist with our advertising efforts. By continuing to use this site, you consent to the use of cookies. For more information on cookies, please take a look at our Privacy Policy. X